Product Characteristics

01. 5Gas (NOX added) Analyzer
02. Durable Performance that has passed a severe
    cold test at -10
03. Automatic Temperature Adjustment (2~8 min)
04. Pause Option Available
05. 6 LED Display Windows
    (CO, HC, CO2, O2, ,AFR/ NOX), and a Built-In Printer
06. Name and Phone Number Memory Option
07. Time and Date Display Option when using printer
08. RS232 PC Program (optional)
09. Suitable for professional engine tune-ups

* Suitable for professional auto smoke testing shops
 

Product Specifications

...QRO-401(5GAS)

Target Subject CO, HC, CO2, O2, (Excess Air Ratio), AFR, NOx
Sensor Theory CO, HC, CO2: Non-Dispersive Infrared Analysis (NDIR)
O2, NOx: Electrochemical Cell
Analysis Range CO 0.00 ~ 9.99% HC 0 ~ 9999 ppm
Resolving Power
0.01% 1 ppm
Display 4 digit 7segment LED 4 digit 7segment LED
Analysis Range CO2 0.0 ~ 20.0% O2 0.00 ~ 25.00 %
Resolving Power
0.1% 0.01 %
Display 4 digit 7segment LED 4 digit 7segment LED
Analysis Range
0 ~ 2.000 NOX 0 ~ 5,000ppm
Resolving Power
0.001 1 ppm
Display 4 digit 7segment LED 4 digit 7segment LED
Repetition Rate
Lower than 2% FS
Response Time
Within 10 seconds (90% of the time)
Preheat Time
Approx. 2~8 minutes
Sample Requirement
4 ~ 6 L/min
Voltage Use
AC110V or AC220V 10%, 50/60Hz
Power Consumption
Approx. 50W
Category Temperature
0 ~ 40
Size
285 (W) * 410 (D) * 155 (H) mm
Weight
Approx. 4.5kg
Included Accessories

Probe, Probe Hose, Emergency Fuse, Water Leak Testing Cap, Emergency Filter, Instruction Manual, Power Cord, Ground Wire, and Type Approval Certificate

Optional Accessories Printer, Printer Paper, RS232